Skip to content

JOINWE

JWJ4 Oil Particle Counter Sensor

Manufacturer product description

JWJ4 oil particle counter sensor is developed based on the light blockage method method (photoresistance method) principle, which is used for on-line real-time monitoring of particle pollution in the oil circuit of hydraulic system.

JWJ4 Oil Particle Counter Sensor

JWJ4 Oil Particle Counter Sensor
Brand
JOINWE
Category
Online Oil Monitoring System
Method / product family
Model
JWJ4

Technical Specifications

Meas urement I ndicators — Testing range1~100 µm | 4~70 µm
Meas urement I ndicators — Detection channel1 µm , 2µm, 5µm, 10µm, 15µm, 25µm, 50µm, 100µm / 4µm(c), 4.6µm(c), 6µm(c), 10µm(c), 14µm(c), 21µm(c), 38µm(c), 70µm(c)
Meas urement I ndicators — Detection flow speed10~300mL/min(recommend 25mL/min)
Meas urement I ndicators — Detection period5~60S (5S/time)
Meas urement I ndicators — RepeatabilityRSD < 5%
Meas urement I ndicators — AccuracyP article count ±20% (or ±1 pollution degree)
Meas urement I ndicators — Built-in standardNAS1638, ISO4406
Meas urement I ndicators — NoteM easurement accuracy to ensure that the test environment temperature at 20±5 ℃, low rate of 25 m L /min range.
Electrical parameters — Signal OutputRS485 M ODBUS RTU /ASCII Code
Electrical parameters — Working voltageDC 24 V ±10%
Electrical parameters — Working current< 20 0 mA
Electrical parameters — Illumination typeDiode Laser
Temperature parameters — TemperatureWorking temperature: -20 ℃ -60 ℃; Liquid temperature: 0 ℃ -80 ℃; Storage temperature: -40 ℃ -85 ℃
Structural parameters — Oil Inlet and Outlet PortsG1/ 8-φ6, with 6mm OD low-pressure tubing
Structural parameters — Structural dimensionφ30.5 * 84.4 mm
Structural parameters — IP rateIP65
Structural parameters — Size100mm*75mm*71mm
Other parameters — Allowable Probe Pressure≤ 2 MPa ,2~40MPa(with pressure reducing valves)
Other parameters — Sensor weight800g

Technical specifications are taken from data published by the supplier; refer to the supplier source for final and binding values.

Product Documents

No verified product document has been published for this product yet.

Request a product quote

Add the NDT and PWHT equipment, consumables and spare parts you wish to purchase to your product quote list.