Skip to content

OKOndt Group

Dynamic Rotating Countersink Probe (100˚ angle of chamfer, Differential Unshielded / Shielded)

Manufacturer product description

Dynamic Rotating Countersink Eddy current Probe (100˚ angle of chamfer, Differential Unshielded / Shielded)

Dynamic Rotating Countersink Probe (100˚ angle of chamfer, Differential Unshielded / Shielded)

Dynamic Rotating Countersink Probe (100˚ angle of chamfer, Differential Unshielded / Shielded)
  • Dynamic Rotating Countersink Probe (100˚ angle of chamfer, Differential Unshielded / Shielded) — 2
Brand
OKOndt Group
Category
Eddy current probes
Method / product family

Technical Specifications

Brochure: Eddy current probes — RCP-100˚- 3.17Guide hole diameter “D”, mm/inch: 3.17/.125 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: 4-pin Fischer connector (to Hocking, GE, Rohmann and Forester drive units, etc.) | Material: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 3.96Guide hole diameter “D”, mm/inch: 3.96/.156 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 4Guide hole diameter “D”, mm/inch: 4/.157 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 4.75Guide hole diameter “D”, mm/inch: 4.75/.187 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 5Guide hole diameter “D”, mm/inch: 5/.197 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 6Guide hole diameter “D”, mm/inch: 6/.236 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 6.34Guide hole diameter “D”, mm/inch: 6.34/.25 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 7Guide hole diameter “D”, mm/inch: 7/.276 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 7.92Guide hole diameter “D”, mm/inch: 7.92/.312 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 9Guide hole diameter “D”, mm/inch: 9/.354 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 9.52Guide hole diameter “D”, mm/inch: 9.52/.375 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 11Guide hole diameter “D”, mm/inch: 11/.433 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 11.09Guide hole diameter “D”, mm/inch: 11.09/.437 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 12.69Guide hole diameter “D”, mm/inch: 12.69/.5 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 13Guide hole diameter “D”, mm/inch: 13/.512 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 14.26Guide hole diameter “D”, mm/inch: 14.26/.562 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 15Guide hole diameter “D”, mm/inch: 15/.59 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 15.86Guide hole diameter “D”, mm/inch: 15.86/.625 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 17.44Guide hole diameter “D”, mm/inch: 17.44/.687 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCP-100˚- 19.03Guide hole diameter “D”, mm/inch: 19.03/.75 | Countersink angle, degr.: 100 | Length, mm: 64 | Frequency: 200 kHz -3 MHz | Connector: Fe/NFe
Brochure: Eddy current probes — RCPColumn 2: - | Column 3: 100˚ | Column 4: - | Column 5: 3.17 | Column 6: (SS/Sh)
Brochure: Eddy current probes — 1Column 3: 2 | Column 5: 3 | Column 6: 4

Technical specifications are taken from data published by the supplier; refer to the supplier source for final and binding values.