Guided Ultrasonics
QSR System – QSR1
Manufacturer product description
The QSR1 ® device incorporates the latest guided wave Quantitative Short Range (QSR) technology and hardware. QSR1 ® moves axially along the top of the pipe, sending guided waves around its circumference to generate a thickness profile of the area of interest as described in the QSR ® overview page . The system provides a quantitative measure of remaining pipe wall thickness as well as the average value.
QSR System – QSR1

- Brand
- Guided Ultrasonics
- Category
- Inspection / Scanning / QSR System
- Method / product family
- Model
- QSR1
Technical Specifications
| Clearance | Varies according to diameter: from 210 mm to 170 mm [8.3″ to 6.7″] Special frames available for limited clearance. |
|---|---|
| Communications | USB, LAN |
| Operating Temperature | ‐20°C to 70°C (‐40°F to 160°F) |
| Pipe Diameter | 6″ to 24″ (DN 150 to 600) – Nominal API 5L |
| Pipe Orientation | Horizontal (±15 degrees) |
| Pipe Wall Thickness | 6 mm to 13 mm (0.236″ to 0.512″) |
| Surface Preparation | Surface must be wiped clean of loose debris. Coatings thicker than 1 mm must be removed under the sensor. |
Technical specifications are taken from data published by the supplier; refer to the supplier source for final and binding values.