Technical Specifications

TOFD transducers specification: — inFrequency, MHz: mm | Element dia.: in | Object thickness: mm
TOFD transducers specification: — TWS10-3-TOFD 3/8"Frequency, MHz: 10 | Element dia.: .125 | Object thickness: 3 | Column 5: .390-.600 | Column 6: 10-15
TOFD transducers specification: — TWS10-6-TOFD 3/8"Frequency, MHz: 10 | Element dia.: .250 | Object thickness: 6 | Column 5: .600-1.4 | Column 6: 15-35
TOFD transducers specification: — * TWS5-6-TOFD 3/8"Frequency, MHz: 5 | Element dia.: .250 | Object thickness: 6 | Column 5: 1.4-2.0 | Column 6: 15-50
TOFD transducers specification: — TWS5-12-TOFD M16Frequency, MHz: 5 | Element dia.: .500 | Object thickness: 12 | Column 5: 2.0-4.0 | Column 6: 50-100
TOFD transducers specification: — TWS3-12-TOFD M16Frequency, MHz: 3 | Element dia.: .500 | Object thickness: 12 | Column 5: 4.0-8.0 | Column 6: 100-200
TOFD transducers specification: — TWS2.5-12-TOFD M16Frequency, MHz: 2.5 | Element dia.: .500 | Object thickness: 12 | Column 5: 8.0-6.0 | Column 6: 200-300
TOFD transducers specification: — TWS2.25-12-TOFD M16Frequency, MHz: 2.25 | Element dia.: .500 | Object thickness: 12 | Column 5: 8.0-6.0 | Column 6: 200-300
TOFD transducers specification: — TWS3-8-TOFD M16Frequency, MHz: 3.0 | Element dia.: .325 | Object thickness: 8 | Column 5: 4.0-8.0 | Column 6: 100-200
TOFD transducers specification: — TWS2.5-8-TOFD M16Frequency, MHz: 2.5 | Element dia.: .325 | Object thickness: 8 | Column 5: 4.0-8.0 | Column 6: 100-200
TOFD transducers specification: — TWS2.25-8-TOFD M16Frequency, MHz: 2.25 | Element dia.: .325 | Object thickness: 8 | Column 5: 4.0-8.0 | Column 6: 100-200
TOFD wedges specification: — WS45 L-3/8"-TOFDThread diameter: 3/8" | Refracted angle o: 45
TOFD wedges specification: — WS60 L-3/8"-TOFDThread diameter: 3/8" | Refracted angle o: 60
TOFD wedges specification: — * WS70 L-3/8"-TOFDThread diameter: 3/8" | Refracted angle o: 70
TOFD wedges specification: — WS45 L-M16-TOFDThread diameter: M16 | Refracted angle o: 45
TOFD wedges specification: — WS60 L-M16-TOFDThread diameter: M16 | Refracted angle o: 60
TOFD wedges specification: — WS70 L-M16-TOFDThread diameter: M16 | Refracted angle o: 70
Testing objects parameters — Thicknessesper one path .25 - 2 in (6 - 50 mm); with probe replacement per several paths 50 – 300 mm
Testing objects parameters — Diameter for cylindrical objectsfrom 12 in (300 mm) to flat
Testing objects parameters — Diameter for spherical objectsfrom 16 ft (5 m) to flat
Testing objects parameters — Profile typesany
Scanner TOFD 2.2 Lite — Dimensions (L×W×H)450 × 240 × 120mm
Scanner TOFD 2.2 Lite — Weight2.8 kg
Scanner TOFD 2.2 Lite — Number of TOFD pairs1
Scanner TOFD 2.2 Lite — Coupling liquid supplyindividually for each probe
Compatible probes and wedges — Frequencies1-15 MHz
Compatible probes and wedges — Angles (L-wave)45°, 60°, 70°
Measurement — Number of cursors2
Measurement — Types of cursorsConventional (cross) Hyperbolic
Measurement — Manual positioning✔
Measurement — Automatic positioning✔
Measurement — Absolute measurements✔
Measurement — Relative measurements✔
Measurement — Indications table✔
Measurement — Indications parametersX, X 1 , X 2 , dX Z, Z 1 , Z 2 , dZ Type (Point, Top, Bottom, Middle, Volumetric) Amplitude
Measurement — Unitsmm / in / us
Measurement — Output fields5
Unit connectors — Pulser and Receiver2 × BNC
Unit connectors — Encoder✔
Unit connectors — Power✔
Unit connectors — RS485✔
Unit connectors — LAN✔
Unit connectors — Sync input✔
Unit connectors — Trigger output✔
Pulser — TypeSWP
Pulser — Voltage (SWP)20 V, 30 V, 40 V, 50 V, 80 V, 100 V
Pulser — Energy (SWP)20 ns to 500 ns with 10 ns step
Pulser — PRFfrom 15 to 2000 Hz
Receiver — RangeUp to 100 us
Receiver — DelayUp to 100 us
Receiver — Gain0 to 110 dB, with 0.1 dB step
Receiver — Max signal input20 V p-p
Receiver — Bandwidth0.2 MHz - 27 MHz
Receiver — Filters1 MHz, 2-3 MHz, 4-5 MHz, 10 MHz, 15 MHz, Full band
Receiver — RectificationFull Wave
Receiver — Signal Average2x / 4x / 8x / 16x / 32x